Modular Systems > National Instruments > NI Cables




Or speak to a sales representative for additional information:
MXI-2 Type M3 Request for Availablility
MXI-2 Type M3, Straight-Point or Right-Angle Point Connectors, 1- 2- or 4 Meter, NI Cable
Need an Official Quote?
National Instruments MXI-2 Type M3 cable
The MXI-2 Type M3 cable (Part Numbers: 777165-04, 777165-02, 777165-01) from National Instruments is designed for use in industrial automation and data gathering applications. Capable of either straight-point or right-angle point connections, the cable may be utilized for a range of test and measurement connectivity needs. The cable may be seamlessly integrated into existing settings because it is compatible with ordinary MXI and INTX cables.
With lengths of 1, 2, 4, 8, and 20 meters, the MXI-2 Type M3 cable provides design flexibility to meet various spatial needs inside a system. The temperature range of the cable spans from 0° to 55°C during operation and -40° to 85°C when in storage, providing consistent performance throughout a range of environmental conditions. The cable is resistant to wet environments and can endure noncondensing relative humidity levels between 0% and 95% in both operating and storage settings.
By reducing electromagnetic interference for steady data transmission, it complies with FCC Class A EMI regulations. The MXI-2 Type M3 cable ensures that connected devices receive enough power delivery because it has the electrical capacity to withstand DC currents up to 3.2 A at a typical 2.2 A. Screw locks for safe connections and labeled ends for accurate alignment during setup are just a couple of the user-friendly features built into its design. The Type M3 cable, MXI-2, is essential for connecting to other MXIbus devices, including mainframes, instruments, and personal computers, and for expanding the VMEbus architecture outside of a VMEbus mainframe.
To convert bus cycles between the VMEbus and MXIbus smoothly and enable effective data interchange, it makes use of address mapping. In addition to VMEbus interrupts, VXIbus triggers, VXIbus CLK10, and utility bus signals, the cable extends the capabilities of signals as part of the MXI-2 product line. Along with offering arbitration and priority-selection features, it may also act as the MXI-2 system controller. A further characteristic of the MXI-2 Type M3 cable is its inbuilt termination circuitry, which senses its location in the cable configuration and automatically turns on or off termination as necessary. In order to guarantee correct signal transmission over the network, systems containing several MXI-2 devices must have daisy-chain connections.
Model Name | MXI-2 Type M3 |
---|---|
Part Number(s) | 777165-04, 777165-02, 777165-01, 777178-03 |
Connector Type | Straight-Point or Right-Angle Point |
Cable Compatibility | Standard MXI and INTX Cables |
Lengths Available | 1, 2, 4, 8, and 20 meters |
Temperature Range | 0°C to 55°C (operating), -40°C to 85°C (storage) |
Humidity Range | 0% to 95% noncondensing (operating and storage) |
EMI Compliance | FCC Class A Verified |
Electrical Rating | DC Current: 2.2 A typical, 3.2 A maximum |
Signal Capabilities | VMEbus interrupts, VXIbus triggers, VXIbus CLK10, Utility bus signals (SYSFAIL*, SYSRESET*, ACFAIL*) |
System Integration | Extends VMEbus architecture via MXI-2 |
Address Mapping | Translates bus cycles between VMEbus and MXIbus |
Termination | Onboard termination circuitry for cable end detection |
National Instruments MXI-2 Type M3 Cable Frequently Asked Questions
Why does the MXI-2 Type M3 have different part numbers?
The part numbers identify different lengths of the MXI-2 Type M3 cable. 777165-04: 4 meters, 777165-02: 2 meters, 777165-01: 1 meter.
In what lengths is the MXI-2 Type M3 available?
The MXI-2 Type M3 comes in 1 m, 2 m, 4 m, 8 m, and 20 m lengths.
What connectors does the MXI-2 Type M3 cable feature?
The MXI-2 Type M3 features Straight-Point or Right-Angle Point Connector.
MXI-2 Type M3 PDF Manuals
MXI 2 TYPE M3 DECLARATION OF CONFORMITY.PDF
MXI 2 TYPE M3 DIMENSIONAL DRAWINGS.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
MXI-2 Type M3
Modular Systems > National Instruments > NI Cables
MXI-2 Type M3, Straight-Point or Right-Angle Point Connectors, 1- 2- or 4 Meter, NI Cable
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
- Manuals & PDFs
National Instruments MXI-2 Type M3 cable
The MXI-2 Type M3 cable (Part Numbers: 777165-04, 777165-02, 777165-01) from National Instruments is designed for use in industrial automation and data gathering applications. Capable of either straight-point or right-angle point connections, the cable may be utilized for a range of test and measurement connectivity needs. The cable may be seamlessly integrated into existing settings because it is compatible with ordinary MXI and INTX cables.
With lengths of 1, 2, 4, 8, and 20 meters, the MXI-2 Type M3 cable provides design flexibility to meet various spatial needs inside a system. The temperature range of the cable spans from 0° to 55°C during operation and -40° to 85°C when in storage, providing consistent performance throughout a range of environmental conditions. The cable is resistant to wet environments and can endure noncondensing relative humidity levels between 0% and 95% in both operating and storage settings.
By reducing electromagnetic interference for steady data transmission, it complies with FCC Class A EMI regulations. The MXI-2 Type M3 cable ensures that connected devices receive enough power delivery because it has the electrical capacity to withstand DC currents up to 3.2 A at a typical 2.2 A. Screw locks for safe connections and labeled ends for accurate alignment during setup are just a couple of the user-friendly features built into its design. The Type M3 cable, MXI-2, is essential for connecting to other MXIbus devices, including mainframes, instruments, and personal computers, and for expanding the VMEbus architecture outside of a VMEbus mainframe.
To convert bus cycles between the VMEbus and MXIbus smoothly and enable effective data interchange, it makes use of address mapping. In addition to VMEbus interrupts, VXIbus triggers, VXIbus CLK10, and utility bus signals, the cable extends the capabilities of signals as part of the MXI-2 product line. Along with offering arbitration and priority-selection features, it may also act as the MXI-2 system controller. A further characteristic of the MXI-2 Type M3 cable is its inbuilt termination circuitry, which senses its location in the cable configuration and automatically turns on or off termination as necessary. In order to guarantee correct signal transmission over the network, systems containing several MXI-2 devices must have daisy-chain connections.
Model Name | MXI-2 Type M3 |
---|---|
Part Number(s) | 777165-04, 777165-02, 777165-01, 777178-03 |
Connector Type | Straight-Point or Right-Angle Point |
Cable Compatibility | Standard MXI and INTX Cables |
Lengths Available | 1, 2, 4, 8, and 20 meters |
Temperature Range | 0°C to 55°C (operating), -40°C to 85°C (storage) |
Humidity Range | 0% to 95% noncondensing (operating and storage) |
EMI Compliance | FCC Class A Verified |
Electrical Rating | DC Current: 2.2 A typical, 3.2 A maximum |
Signal Capabilities | VMEbus interrupts, VXIbus triggers, VXIbus CLK10, Utility bus signals (SYSFAIL*, SYSRESET*, ACFAIL*) |
System Integration | Extends VMEbus architecture via MXI-2 |
Address Mapping | Translates bus cycles between VMEbus and MXIbus |
Termination | Onboard termination circuitry for cable end detection |
National Instruments MXI-2 Type M3 Cable Frequently Asked Questions
Why does the MXI-2 Type M3 have different part numbers?
The part numbers identify different lengths of the MXI-2 Type M3 cable. 777165-04: 4 meters, 777165-02: 2 meters, 777165-01: 1 meter.
In what lengths is the MXI-2 Type M3 available?
The MXI-2 Type M3 comes in 1 m, 2 m, 4 m, 8 m, and 20 m lengths.
What connectors does the MXI-2 Type M3 cable feature?
The MXI-2 Type M3 features Straight-Point or Right-Angle Point Connector.
MXI-2 Type M3 PDF Manuals & Diagrams
MXI-2 Type M3 PDF Manuals
MXI 2 TYPE M3 DECLARATION OF CONFORMITY.PDF
MXI 2 TYPE M3 DIMENSIONAL DRAWINGS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."